# Experiment 01 - Sensor Calibration
|
|
|
|
## Purpose
|
|
|
|
The purpose of experiment 1 is to map the analog output values of the hydration
|
|
sensor to different levels of water concentration in soil. This mapping will be
|
|
necessary to adjust the user experience of the final device.
|
|
|
|
## Components and equipment
|
|
|
|
- Arduino board to run code
|
|
- Three male to male jumper cables
|
|
- One moisture sensor
|
|
- A cup of soil
|
|
- Water
|
|
|
|
## Methodology
|
|
|
|
1. Prepare the sensor. The power input should come from the 5V output of the
|
|
board. This is important since different voltage inputs to the sensor will
|
|
alter the obtained measurements for an identical humidity.
|
|
2. Prepare the code. Three versions of the code will be used raw, slightly
|
|
smoothed and heavily smoothed.
|
|
- Raw version outputs the sensor's measurement to the serial port in
|
|
real-time, unfiltered.
|
|
- The slightly smoothed version will take 10 measurements with 50ms of
|
|
delay between each and return the mean.
|
|
- The heavily smoothe version will take 100 measurements with 50ms of delay
|
|
between each and return the mean.
|
|
3. Prepare the soil
|
|
- In a small recipient (weight: 80g), place 200g of soil.
|
|
- Let it dry for X days (collection on 24/10/2022) to obtain the driest
|
|
possible soil.
|
|
4. The next steps will be performed repeteadly by adding 10ml of water to the
|
|
soil at each step. Start by first measuring the completely dry-soil. Ensure
|
|
that the water is distributed uniformly across the soil. For each amount of
|
|
water up to a max of 200ml, and for each version of the code:
|
|
- Obtain measurements from the sensor. If the measurement is unstable,
|
|
record the observed range and the most frequent value.
|
|
5. Finally, obtain measurements in a glass of pure water, with no soil at all.
|
|
|
|
## Results
|
|
|
|
See file `exp01_sensor_calibration.ods`.
|
|
|
|
## Conclusions
|
|
|
|
The results where a bit dissapointing. The sensor signal was clearly moving
|
|
when the dry soil received the first 10ml of water. But, from that point on,
|
|
the next additions of water barely modified the returned signal. Eventually,
|
|
there was no significant change in the sensor values. This is showing a
|
|
sensitivity way below what I was expecting.
|
|
|
|
I have been reading about some modifications in the circuit to improve the
|
|
accuracy of the sensor. I'll design another experiment to try them out. |