# Nodito CPU Temperature Monitoring Configuration # Temperature Monitoring Configuration temp_threshold_celsius: 80 temp_check_interval_minutes: 1 # Script Configuration monitoring_script_dir: /opt/nodito-monitoring monitoring_script_path: "{{ monitoring_script_dir }}/cpu_temp_monitor.sh" log_file: "{{ monitoring_script_dir }}/cpu_temp_monitor.log" # System Configuration systemd_service_name: nodito-cpu-temp-monitor # ZFS Pool Configuration zfs_pool_name: "proxmox-tank-1" # Corrected 2026-09-13: this said WX11TN0Z, a disk that is no longer in the # machine. The live mirror is WX120LHQ + WX11TN2P - a leg was evidently # replaced and the repo never caught up. Pool creation is guarded by # `when: zfs_pool_exists.rc != 0` so it was inert, but it would have been # wrong on any disaster-recovery run. zfs_disk_1: "/dev/disk/by-id/ata-ST4000NT001-3M2101_WX120LHQ" # First disk for RAID 1 mirror zfs_disk_2: "/dev/disk/by-id/ata-ST4000NT001-3M2101_WX11TN2P" # Second disk for RAID 1 mirror zfs_pool_mountpoint: "/var/lib/vz" # UPS Configuration (CyberPower CP900EPFCLCD via USB) ups_name: cyberpower ups_desc: "CyberPower CP900EPFCLCD" ups_driver: usbhid-ups ups_port: auto ups_user: counterweight ups_offdelay: 120 # Seconds after shutdown before UPS cuts outlet power ups_ondelay: 30 # Seconds after mains returns before UPS restores outlet power